OBJECT = SCDATASET DATA_SET_ID = "IRAS-D-FPA-6-RDR-V1.0" OBJECT = DATASETINFO DATA_SET_NAME = "IRAS SPECTRAL RESPONSE V1.0" DATA_SET_COLLECTION_MEMBER_FLG = "N" START_TIME = "N/A" STOP_TIME = "N/A" NATIVE_START_TIME = "N/A" NATIVE_STOP_TIME = "N/A" DATA_OBJECT_TYPE = TABLE DATA_SET_RELEASE_DATE = 1993-04-26 /* Peer Review Date */ PROCESSING_LEVEL_ID = 3 PRODUCER_FULL_NAME = "MARK V. SYKES" PRODUCER_INSTITUTION_NAME = "UNIVERSITY OF ARIZONA" SOFTWARE_FLAG = "N" DETAILED_CATALOG_FLAG = "N" PROCESSING_START_TIME = "N/A" PROCESSING_STOP_TIME = "N/A" DATA_SET_DESC = " The Infrared Astronomical Satellite provides radiometry for the celestial sphere in four filter passbands. This dataset contains the detailed optical system transmission, detector spectral response, and overall relative spectral response for each band." CONFIDENCE_LEVEL_NOTE = "The detector spectral response of the Ge:Ga detectors used at 100 microns was assumed to be the same as that of the 60 micron detectors even though the material came from a different source. Limits on out-of-band leaks, at short and long wavelengths, are tabulated in Beichman etal 1988. At 12 and 25 microns, these leaks effect the calibration by less than 0.02 percent. At 60 and 100 microns, the effect is less than 10 percent." END_OBJECT = DATASETINFO OBJECT = DATASETTARG TARGET_NAME = "N/A" END_OBJECT = DATASETTARG OBJECT = DSPARMINFO SAMPLING_PARAMETER_NAME = WAVE_12 SAMPLING_PARAMETER_RESOLUTION = "N/A" MINIMUM_SAMPLING_PARAMETER = 7.0 MAXIMUM_SAMPLING_PARAMETER = 15.5 SAMPLING_PARAMETER_INTERVAL = 0.5 MINIMUM_AVAILABLE_SAMPLING_INT = "N/A" SAMPLING_PARAMETER_UNIT = MICROMETER DATA_SET_PARAMETER_NAME = "N/A" NOISE_LEVEL = "N/A" DATA_SET_PARAMETER_UNIT = "N/A" END_OBJECT = DSPARMINFO OBJECT = DSPARMINFO SAMPLING_PARAMETER_NAME = WAVE_25 SAMPLING_PARAMETER_RESOLUTION = "N/A" MINIMUM_SAMPLING_PARAMETER = 16.0 MAXIMUM_SAMPLING_PARAMETER = 31.5 SAMPLING_PARAMETER_INTERVAL = 0.5 MINIMUM_AVAILABLE_SAMPLING_INT = "N/A" SAMPLING_PARAMETER_UNIT = MICROMETER DATA_SET_PARAMETER_NAME = "N/A" NOISE_LEVEL = "N/A" DATA_SET_PARAMETER_UNIT = "N/A" END_OBJECT = DSPARMINFO OBJECT = DSPARMINFO SAMPLING_PARAMETER_NAME = WAVE_60 SAMPLING_PARAMETER_RESOLUTION = "N/A" MINIMUM_SAMPLING_PARAMETER = 27.0 MAXIMUM_SAMPLING_PARAMETER = 87.0 SAMPLING_PARAMETER_INTERVAL = 3.0 MINIMUM_AVAILABLE_SAMPLING_INT = "N/A" SAMPLING_PARAMETER_UNIT = MICROMETER DATA_SET_PARAMETER_NAME = "N/A" NOISE_LEVEL = "N/A" DATA_SET_PARAMETER_UNIT = "N/A" END_OBJECT = DSPARMINFO OBJECT = DSPARMINFO SAMPLING_PARAMETER_NAME = WAVE_100 SAMPLING_PARAMETER_RESOLUTION = "N/A" MINIMUM_SAMPLING_PARAMETER = 65.0 MAXIMUM_SAMPLING_PARAMETER = 140.0 SAMPLING_PARAMETER_INTERVAL = 5.0 MINIMUM_AVAILABLE_SAMPLING_INT = "N/A" SAMPLING_PARAMETER_UNIT = MICROMETER DATA_SET_PARAMETER_NAME = "N/A" NOISE_LEVEL = "N/A" DATA_SET_PARAMETER_UNIT = "N/A" END_OBJECT = DSPARMINFO OBJECT = SCDSHOST INSTRUMENT_HOST_ID = IRAS INSTRUMENT_ID = FPA END_OBJECT = SCDSHOST OBJECT = DSREFINFO REFERENCE_KEY_ID = "BEICHMANETAL1988" END_OBJECT = DSREFINFO END_OBJECT = SCDATASET END