PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "NULL" OBJECT = INSTRUMENT_HOST INSTRUMENT_HOST_ID = "IRAS" OBJECT = INSTRUMENT_HOST_INFORMATION INSTRUMENT_HOST_NAME = "INFRARED ASTRONOMICAL SATELLITE" INSTRUMENT_HOST_TYPE = "SPACECRAFT" INSTRUMENT_HOST_DESC = " Instrument Host Overview ======================== The Infrared Astronomical Satellite (IRAS) was a spacecraft with a telescope mounted in a liquid helium cooled cryostat. The telescope was a f/9.6 Ritchey-Chretien design with a 5.5 m focal length and a 0.57 m aperture. The mirrors were made of beryllium and cooled to approximately 4 K. The focal plane assembly contained the survey detectors, visible star sensors for position reconstruction, a Low Resolution Spectrometer (LRS) and a Chopped Photometric Channel (CPC). The focal plane assembly was located at the Cassegrain focus of the telescope and was cooled to about 3 K. The survey array consisted of 62 rectangular infrared detectors arranged in staggered rows such that any real point source crossing the focal plane as the satellite scanned would be seen by at least two detectors in each wavelength band. Most of the detectors in each band had standard size apertures (see table below), with one or two being half-sized. The LRS was a slitless spectrometer sensitive from 7.5 to 23 microns with a resolving power of about 20. The CPC operated during some pointed observations. It mapped sources simultaneously at 50 and 100 microns, and used a cold internal chopper for flux reference. However, the focal plane temperature was lower than expected, which resulted in CPC detector anomalies that rendered CPC data very difficult to use. Instrument Summary ------------------ In the table below, the center wavelengths are in microns. For the survey array, the FOV is determined by the rather large detector mask size and is roughly the native 'resolution' of the data in that band. The resolution of the IRAS image data is not governed by the resolution of the telescope, which was diffraction limited longwards of 12 microns, but by the size of the detectors. ------------------------------------------------------------------ SURVEY ARRAY Center # working FOV Bandpass Detector Average 10-sigma Wavelength detectors (arcmin) (micron) Material Sensitivity (Jy) 12 16 .75 x 4.5 8.5- 15 Si:As 0.7 25 13 .75 x 4.6 19 - 30 Si:Sb 0.65 60 15 1.5 x 4.7 40 - 80 Ge:Ga 0.85 100 13 3.0 x 5.0 83 -120 Ge:Ga 3.0 ------------------------------------------------------------------ CPC Center # working FOV Bandpass Detector Average 10-sigma Wavelength detectors (arcmin) (micron) Material Sensitivity (Jy) 50 1 1.2 41 - 63 Ge:Ga 7.0 100 1 1.2 84 -114 Ge:Ga 7.0 ------------------------------------------------------------------ LRS Slit width Wavelength Range Detector Resolving (arcmin) (micron) Material Power 5.0 8 - 13 Si:Ga 14-35 7.5 11 - 23 Si:As 14-35 ------------------------------------------------------------------" END_OBJECT = INSTRUMENT_HOST_INFORMATION OBJECT = INSTRUMENT_HOST_REFERENCE_INFO REFERENCE_KEY_ID = "NEUGEBAUERETAL1984" END_OBJECT = INSTRUMENT_HOST_REFERENCE_INFO OBJECT = INSTRUMENT_HOST_REFERENCE_INFO REFERENCE_KEY_ID = "BEICHMANETAL1988" END_OBJECT = INSTRUMENT_HOST_REFERENCE_INFO END_OBJECT = INSTRUMENT_HOST END