OBJECT = COLUMN NAME = "SCET_UTC" DATA_TYPE = TIME UNIT = "N/A" START_BYTE = 1 BYTES = 19 FORMAT = "A19" DESCRIPTION = " The UTC spacecraft event time (SCET) determined from the packet's SCLK value. The time format is yyyy-mm-ddThr:mn:sc. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "STATE_INDEX" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 20 BYTES = 5 FORMAT = "I5" VALID_MAXIMUM = 9999 DESCRIPTION = " The state index is a counter that starts at 0 and increments every time the state changes. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "DELTA_SCLK" DATA_TYPE = ASCII_INTEGER UNIT = "SECONDS" START_BYTE = 25 BYTES = 8 FORMAT = "I8" VALID_MAXIMUM = 9999 MISSING_CONSTANT = -999 DESCRIPTION = " The number of SCLK ticks (seconds) that the instrument was in the state. When only one state is present, then the duration is unknown. The last state for a file with multiple states has an unknown duration. These states are assigned the MISSING_CONSTANT. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "SCLK" DATA_TYPE = ASCII_INTEGER UNIT = "SECONDS" START_BYTE = 33 BYTES = 11 FORMAT = "I11" VALID_MAXIMUM = 4294967295 DESCRIPTION = " Spacecraft clock count at the start of the SOH interval. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TELREADOUT" DATA_TYPE = ASCII_INTEGER UNIT = "SECONDS" START_BYTE = 44 BYTES = 6 FORMAT = "I6" VALID_MINIMUM = 15 VALID_MAXIMUM = 2000 DESCRIPTION = " Measurement interval for the science data. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "TELSOH" DATA_TYPE = ASCII_INTEGER UNIT = "SECONDS" START_BYTE = 50 BYTES = 6 FORMAT = "I6" VALID_MINIMUM = 2 VALID_MAXIMUM = 2000 DESCRIPTION = " Measurement interval for the state-of-health readout. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "MODE" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 56 BYTES = 2 FORMAT = "I2" DESCRIPTION = " Instrument mode (0=Standby, 1=Normal, 2=Anneal) " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS1_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 58 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 1, which supplies the photomultiplier tube for the +Z phoswich. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS1" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 67 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS1 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS2_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 69 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 2, which supplies the photomultiplier tube for the -Z phoswich. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS2" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 78 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS2 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS3_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 80 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 3, which supplies the photomultiplier tube for the -Y boron-loaded plastic scintillator. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS3" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 89 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS3 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS4_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 91 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 4, which supplies the photomultiplier tube for the +Y boron-loaded plastic scintillator. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS4" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 100 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS4 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS5_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 102 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 5, which supplies the photomultiplier tube for the BGO scintillator. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS5" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 111 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS5 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS6_SET" DATA_TYPE = ASCII_REAL UNIT = "VOLTS" START_BYTE = 113 BYTES = 9 FORMAT = "F9.2" DESCRIPTION = " Set point for high voltage power supply (HVPS) 6, which provides the bulk bias for the CZT array. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "HVPS6" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 122 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, then HVPS6 is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "PM5_LVPS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 124 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, the analog +/-5V low voltage power supply is enabled. The supply provides power for analog and digital components, including the scintillator pulse processing electronics and internal sensors (temperature and voltage). " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "P12_LVPS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 126 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, the +12V low power supply is enabled, which supplies the high voltage power supplies (if MODE=1) and the resistive heaters (if MODE=2) used to anneal the CZT array. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CZT_PM5_LVPS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 128 BYTES = 2 FORMAT = "I2" VALID_MAXIMUM = 1 DESCRIPTION = " If 1, the +/-5V supply for the CZT analog pulse processing circuits is enabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "CZT_ENABLES" DATA_TYPE = CHARACTER UNIT = "N/A" START_BYTE = 130 BYTES = 17 FORMAT = "A17" DESCRIPTION = " Bit pattern indicating the state (1=disabled, 0=enabled) of each of the 16 CZT sensors, represented as a character string. For readability, the first character is blank. The remaining characters represent bits, read right to left, which give the state of the 16 sensors in order from 0-15. For example, the pattern 1111111111111110 indicates that all of the CZT sensors are disabled except for sensor 0. The pattern 0010000000000010 indicates that two of the sensors (1 and 13) are disabled. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NEMG_TOT_EVTS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 147 BYTES = 5 FORMAT = "I5" VALID_MAXIMUM = 6676 DESCRIPTION = " Total number of gamma ray events recorded in the science data file. Note that NEMG_TOT_EVTS + NEMN_TOT_EVTS is always less than or equal to 6676. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NEMG_CZT_EVTS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 152 BYTES = 5 FORMAT = "I5" VALID_MAXIMUM = 6676 DESCRIPTION = " The number of CZT single interaction (CAT10) events recorded in the event buffer. This value is always less than NEMG_TOT_EVTS. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "NEMN_TOT_EVTS" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 157 BYTES = 5 FORMAT = "I5" VALID_MAXIMUM = 6676 DESCRIPTION = " Total number of neutron events recorded in the science data file. Note that NEMG_TOT_EVTS + NEMN_TOT_EVTS is always less than or equal to 6676. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BGO_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 162 BYTES = 5 FORMAT = "I5" VALID_MINIMUM = 0 VALID_MAXIMUM = 1023 DESCRIPTION = " Lower channel (output of the BGO ADC)for the CAT2 coincidence window for the BGO sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BGO_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 167 BYTES = 5 FORMAT = "I5" VALID_MINIMUM = 0 VALID_MAXIMUM = 1023 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 coincidence window for the BGO sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BGO_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 172 BYTES = 5 FORMAT = "I5" VALID_MINIMUM = 0 VALID_MAXIMUM = 1023 DESCRIPTION = " Lower channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for the BGO spectrum. Note that H_BGO_ROI - L_BGO_ROI = 64. The window gives range of channels for the CAT2 BGO pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BGO_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 177 BYTES = 5 FORMAT = "I5" VALID_MINIMUM = 0 VALID_MAXIMUM = 1023 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for the BGO spectrum. Note that H_BGO_ROI - L_BGO_ROI = 64. The window gives range of channels for the CAT2 BGO pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_MY_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 182 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 coincidence window for the -Y BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_MY_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 186 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BLP ADC)for the CAT2 coincidence window for the -Y BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_MY_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 190 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 region of interest (ROI) for BLP -Y. Note that H_BLP_MY_ROI - L_BLP_MY_ROI = 64. The window gives the range of channels for the CAT2 BLP -Y pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_MY_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 194 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for BLP -Y. Note that H_BLP_MY_ROI - L_BLP_MY_ROI = 64. The window gives range of channels for the CAT2 BLP -Y pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_PY_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 198 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 coincidence window for the +Y BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_PY_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 202 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BLP ADC)for the CAT2 coincidence window for the +Y BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_PY_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 206 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 region of interest (ROI) for BLP +Y. Note that H_BLP_PY_ROI - L_BLP_PY_ROI = 64. The window gives the range of channels for the CAT2 BLP +Y pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_PY_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 210 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for BLP +Y. Note that H_BLP_PY_ROI - L_BLP_PY_ROI = 64. The window gives range of channels for the CAT2 BLP +Y pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_MZ_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 214 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 coincidence window for the -Z BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_MZ_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 218 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BLP ADC)for the CAT2 coincidence window for the -Z BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_MZ_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 222 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 region of interest (ROI) for BLP -Z. Note that H_BLP_MZ_ROI - L_BLP_MZ_ROI = 64. The window gives the range of channels for the CAT2 BLP -Z pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_MZ_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 226 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for BLP -Z. Note that H_BLP_MZ_ROI - L_BLP_MZ_ROI = 64. The window gives range of channels for the CAT2 BLP -Z pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_PZ_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 230 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 coincidence window for the +Z BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_PZ_CW" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 234 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BLP ADC)for the CAT2 coincidence window for the +Z BLP sensor. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "L_BLP_PZ_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 238 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Lower channel (output of the BLP ADC)for the CAT2 region of interest (ROI) for BLP +Z. Note that H_BLP_PZ_ROI - L_BLP_PZ_ROI = 64. The window gives the range of channels for the CAT2 BLP +Z pulse height spectra. " END_OBJECT = COLUMN OBJECT = COLUMN NAME = "H_BLP_PZ_ROI" DATA_TYPE = ASCII_INTEGER UNIT = "N/A" START_BYTE = 242 BYTES = 4 FORMAT = "I4" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 DESCRIPTION = " Upper channel (output of the BGO ADC)for the CAT2 region of interest (ROI) for BLP +Z. Note that H_BLP_PZ_ROI - L_BLP_PZ_ROI = 64. The window gives range of channels for the CAT2 BLP +Z pulse height spectra. " END_OBJECT = COLUMN