OBJECT                 = COLUMN
  NAME                  = "SCET_UTC"
  DATA_TYPE             = TIME
  UNIT                  = "N/A"
  START_BYTE            = 1
  BYTES                 = 19
  FORMAT                = "A19"
  DESCRIPTION           = "                                                   
     The UTC spacecraft event time (SCET) determined from the packet's SCLK 
     value.  The time format is yyyy-mm-ddThr:mn:sc.
  "
 END_OBJECT             = COLUMN
 
 OBJECT                 = COLUMN
  NAME                  = "STATE_INDEX"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 20
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MAXIMUM         = 9999
  DESCRIPTION           = "                                                   
     The state index is a counter that starts at 0 and increments every
     time the state changes.
  "
 END_OBJECT             = COLUMN
 
 OBJECT                 = COLUMN
  NAME                  = "DELTA_SCLK"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "SECONDS"
  START_BYTE            = 25
  BYTES                 = 8
  FORMAT                = "I8"
  VALID_MAXIMUM         = 9999
  MISSING_CONSTANT      = -999
  DESCRIPTION           = "                                                   
     The number of SCLK ticks (seconds) that the instrument was in the
     state.  When only one state is present, then the duration is unknown.
     The last state for a file with multiple states has an unknown
     duration.  These states are assigned the MISSING_CONSTANT.
  "
 END_OBJECT             = COLUMN
 
 OBJECT                 = COLUMN
  NAME                  = "SCLK"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "SECONDS"
  START_BYTE            = 33
  BYTES                 = 11
  FORMAT                = "I11"
  VALID_MAXIMUM         = 4294967295
  DESCRIPTION           = "                                                   
     Spacecraft clock count at the start of the SOH interval.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "TELREADOUT"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "SECONDS"
  START_BYTE            = 44
  BYTES                 = 6
  FORMAT                = "I6"
  VALID_MINIMUM         = 15
  VALID_MAXIMUM         = 2000
  DESCRIPTION           = "                                                   
     Measurement interval for the science data.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "TELSOH"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "SECONDS"
  START_BYTE            = 50
  BYTES                 = 6
  FORMAT                = "I6"
  VALID_MINIMUM         = 2
  VALID_MAXIMUM         = 2000
  DESCRIPTION           = "                                                   
     Measurement interval for the state-of-health readout.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "MODE"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 56
  BYTES                 = 2
  FORMAT                = "I2"
  DESCRIPTION           = "                                                   
     Instrument mode (0=Standby, 1=Normal, 2=Anneal)
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS1_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 58
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 1, which supplies the 
     photomultiplier tube for the +Z phoswich.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS1"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 67
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS1 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS2_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 69
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 2, which supplies the 
     photomultiplier tube for the -Z phoswich.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS2"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 78
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS2 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS3_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 80
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 3, which supplies the 
     photomultiplier tube for the -Y boron-loaded plastic scintillator.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS3"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 89
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS3 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS4_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 91
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 4, which supplies the 
     photomultiplier tube for the +Y boron-loaded plastic scintillator.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS4"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 100
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS4 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS5_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 102
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 5, which supplies the 
     photomultiplier tube for the BGO scintillator.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS5"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 111
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS5 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS6_SET"
  DATA_TYPE             = ASCII_REAL
  UNIT                  = "VOLTS"
  START_BYTE            = 113
  BYTES                 = 9
  FORMAT                = "F9.2"
  DESCRIPTION           = "                                                   
     Set point for high voltage power supply (HVPS) 6, which provides the bulk
     bias for the CZT array.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "HVPS6"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 122
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, then HVPS6 is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "PM5_LVPS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 124
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, the analog +/-5V low voltage power supply is enabled.  The supply
     provides power for analog and digital components, including the 
     scintillator pulse processing electronics and internal sensors 
     (temperature and voltage).
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "P12_LVPS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 126
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, the +12V low power supply is enabled, which supplies the high
     voltage power supplies (if MODE=1) and the resistive heaters (if MODE=2)
     used to anneal the CZT array.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "CZT_PM5_LVPS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 128
  BYTES                 = 2
  FORMAT                = "I2"
  VALID_MAXIMUM         = 1
  DESCRIPTION           = "                                                   
     If 1, the +/-5V supply for the CZT analog pulse processing circuits 
     is enabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "CZT_ENABLES"
  DATA_TYPE             = CHARACTER
  UNIT                  = "N/A"
  START_BYTE            = 130
  BYTES                 = 17
  FORMAT                = "A17"
  DESCRIPTION           = "                                                   
     Bit pattern indicating the state (1=disabled, 0=enabled) of each of the
     16 CZT sensors, represented as a character string.  For readability,
     the first character is blank.  The remaining characters represent bits, 
     read right to left, which give the state of the 16 sensors in order from 
     0-15. For example, the pattern 1111111111111110 indicates that all of 
     the CZT sensors are disabled except for sensor 0.  The pattern 
     0010000000000010 indicates that two of the sensors (1 and 13) are 
     disabled.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "NEMG_TOT_EVTS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 147
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MAXIMUM         = 6676
  DESCRIPTION           = "                                                   
     Total number of gamma ray events recorded in the science data file. Note
     that NEMG_TOT_EVTS + NEMN_TOT_EVTS is always less than or equal to
     6676.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "NEMG_CZT_EVTS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 152
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MAXIMUM         = 6676
  DESCRIPTION           = "                                                   
     The number of CZT single interaction (CAT10) events recorded in the
     event buffer.  This value is always less than NEMG_TOT_EVTS.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "NEMN_TOT_EVTS"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 157
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MAXIMUM         = 6676
  DESCRIPTION           = "                                                   
     Total number of neutron events recorded in the science data file. Note
     that NEMG_TOT_EVTS + NEMN_TOT_EVTS is always less than or equal to
     6676.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BGO_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 162
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 1023
  DESCRIPTION           = "                                                   
     Lower channel (output of the BGO ADC)for the CAT2 coincidence window 
     for the BGO sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BGO_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 167
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 1023
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 coincidence window 
     for the BGO sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BGO_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 172
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 1023
  DESCRIPTION           = "                                                   
     Lower channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for the BGO spectrum.  Note that H_BGO_ROI - L_BGO_ROI = 64.  
     The window gives range of channels for the CAT2 BGO pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BGO_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 177
  BYTES                 = 5
  FORMAT                = "I5"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 1023
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for the BGO spectrum.  Note that H_BGO_ROI - L_BGO_ROI = 64.  
     The window gives range of channels for the CAT2 BGO pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_MY_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 182
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the -Y BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_MY_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 186
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the -Y BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_MY_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 190
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 region of interest
     (ROI) for BLP -Y. Note that H_BLP_MY_ROI - L_BLP_MY_ROI = 64.  The window
     gives the range of channels for the CAT2 BLP -Y pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_MY_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 194
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for BLP -Y. Note that H_BLP_MY_ROI - L_BLP_MY_ROI = 64.  The window
     gives range of channels for the CAT2 BLP -Y pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_PY_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 198
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the +Y BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_PY_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 202
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the +Y BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_PY_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 206
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 region of interest
     (ROI) for BLP +Y. Note that H_BLP_PY_ROI - L_BLP_PY_ROI = 64.  The window
     gives the range of channels for the CAT2 BLP +Y pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_PY_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 210
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for BLP +Y. Note that H_BLP_PY_ROI - L_BLP_PY_ROI = 64.  The window
     gives range of channels for the CAT2 BLP +Y pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_MZ_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 214
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the -Z BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_MZ_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 218
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the -Z BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_MZ_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 222
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 region of interest
     (ROI) for BLP -Z. Note that H_BLP_MZ_ROI - L_BLP_MZ_ROI = 64.  The window
     gives the range of channels for the CAT2 BLP -Z pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_MZ_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 226
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for BLP -Z. Note that H_BLP_MZ_ROI - L_BLP_MZ_ROI = 64.  The window
     gives range of channels for the CAT2 BLP -Z pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_PZ_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 230
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the +Z BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_PZ_CW"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 234
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BLP ADC)for the CAT2 coincidence window 
     for the +Z BLP sensor. 
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "L_BLP_PZ_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 238
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Lower channel (output of the BLP ADC)for the CAT2 region of interest
     (ROI) for BLP +Z. Note that H_BLP_PZ_ROI - L_BLP_PZ_ROI = 64.  The window
     gives the range of channels for the CAT2 BLP +Z pulse height spectra.
  "
 END_OBJECT             = COLUMN

 OBJECT                 = COLUMN
  NAME                  = "H_BLP_PZ_ROI"
  DATA_TYPE             = ASCII_INTEGER
  UNIT                  = "N/A"
  START_BYTE            = 242
  BYTES                 = 4
  FORMAT                = "I4"
  VALID_MINIMUM         = 0
  VALID_MAXIMUM         = 255
  DESCRIPTION           = "                                                   
     Upper channel (output of the BGO ADC)for the CAT2 region of interest
     (ROI) for BLP +Z. Note that H_BLP_PZ_ROI - L_BLP_PZ_ROI = 64.  The window
     gives range of channels for the CAT2 BLP +Z pulse height spectra.
  "
 END_OBJECT             = COLUMN