OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "SCET_UTC" DATA_TYPE = TIME START_BYTE = 1 BYTES = 19 FORMAT = "A19" DESCRIPTION = " The UTC spacecraft event time (SCET) at the middle of each time interval in the series. The time format is yyyy-mm-ddThr:mn:sc. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "CAT1_PZ_BLP" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 20 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area of the 93 keVeq peak in the CAT1 spectrum from the 10B(n,alpha) reaction for the +Z phoswich. Because the scintillator is shielded by Gd and Li-glass, CAT1_PZ_BLP is due primarily to neutrons in the epithermal energy range (between 0.3 eV and 0.7 MeV). " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "CAT1_PZ_BLP_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 30 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_PZ_BLP_SIGMA. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "CAT1_PZ_LIG" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 40 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area of the peak in the CAT1 spectrum from the 6Li(n,t) reaction for the +Z phoswich. CAT1_PZ_LIG is sensitive to thermal (<0.3 eV)and epithermal neutrons. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "CAT1_PZ_LIG_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 50 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_PZ_LIG. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "CAT2_MZ" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 60 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area for the 478 keV peak from the CAT2 coincidence between the BGO and -Z BLP scintillators. The peak results from the deposition of 93 keVee by the 10B(n,alpha) reaction products in the BLP in coincidence with the deposition of 478 keV in the BGO scintillator. Since the -Z scintillator is shielded by Gd and Li-glass, CAT2_MZ is primarily sensitive to epithermal neutrons (between 0.3 eV and 0.7 MeV). " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "CAT2_MZ_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 70 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_MZ. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "CAT2_MY" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 80 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area for the 478 keV peak from the CAT2 coincidence between the BGO and -Y BLP scintillators. The peak results from the deposition of 93 keVee by the 10B(n,alpha) reaction products in the BLP in coincidence with the deposition of 478 keV in the BGO scintillator. Since the -Y BLP is unshielded, CAT2_MY is sensitive to thermal and epithermal neutrons. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "CAT2_MY_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 90 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_MY. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = "CAT2_PY" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 100 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area for the 478 keV peak from the CAT2 coincidence between the BGO and +Y BLP scintillators. The peak results from the deposition of 93 keVee by the 10B(n,alpha) reaction products in the BLP in coincidence with the deposition of 478 keV in the BGO scintillator. Since the +Y BLP is unshielded, CAT2_PY is sensitive to thermal and epithermal neutrons. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = "CAT2_PY_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 110 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_PY. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "CAT2_PZ" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 120 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Net area for the 478 keV peak from the CAT2 coincidence between the BGO and +Z BLP scintillators. The peak results from the deposition of 93 keVee by the 10B(n,alpha) reaction products in the BLP in coincidence with the deposition of 478 keV in the BGO scintillator. Since the +Z scintillator is shielded by Gd and Li-glass, CAT2_PZ is primarily sensitive to epithermal neutrons (between 0.3 eV and 0.7 MeV). " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "CAT2_PZ_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 130 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in CAT1_PZ. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "FAST_MZ" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 140 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Fast neutron counting rate measured by the -Z BLP scintillator, determined from the event buffer and scaler counting data. FAST_MZ is sensitive to neutrons with energies greater than 0.7 MeV. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "FAST_MZ_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 150 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in FAST_MZ. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "FAST_MY" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 160 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Fast neutron counting rate measured by the -Y BLP scintillator, determined from the event buffer and scaler counting data. FAST_MY is sensitive to neutrons with energies greater than 0.7 MeV. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "FAST_MY_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 170 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in FAST_MY. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "FAST_PY" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 180 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Fast neutron counting rate measured by the +Y BLP scintillator, determined from the event buffer and scaler counting data. FAST_PY is sensitive to neutrons with energies greater than 0.7 MeV. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = "FAST_PY_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 190 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in FAST_PY. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = "FAST_PZ" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 200 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Fast neutron counting rate measured by the +Z BLP scintillator, determined from the event buffer and scaler counting data. FAST_PZ is sensitive to neutrons with energies greater than 0.7 MeV. " END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = "FAST_PZ_SIGMA" DATA_TYPE = ASCII_REAL UNIT = "COUNTS/SECOND" START_BYTE = 210 BYTES = 10 FORMAT = "F10.5" DESCRIPTION = " Estimated uncertainty (1-sigma) in FAST_PZ. " END_OBJECT = COLUMN